China Galvanized Guy Wire Stay Plate Bow Rod

Technics: Forging
Standard: IEC-61284
Usage: Substation Fittings, Line Fittings
Type: Pull-Line Fitting
Material: H.D.G Steel
ODM OEM: Accept
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
RL
Bolts
Not Less Than 6.8 Grade
Samples
Free
Galvanization Type
Hot-DIP Galvanized
Galvanization Standard
ISO 1461-2009
Surface
Smooth
Warranty
12 Months
Application
Guy Wire Fitting
Transport Package
Wooden Case
Specification
Steel
Trademark
Da Sheng
Origin
Yangzhou City, China
HS Code
8535900090
Production Capacity
100000 Pieces/Month

Product Description

China Galvanized Guy Wire Stay Plate Bow Rod

Reasons for Corrosion of Stay Rod:
In the process of overhead line reconstruction, by excavating and inspecting the stay rod and the down lead grounding wire of the old tower, It is found that most of the down lead grounding wire and the stay rod above the ground are intact, but 20~40cm below the ground are seriously corroded, the most serious corrosion is up to 3/4, and the breakage of the stay rod will occurred at any time.

According to the statistics of the excavation and inspection records for the two rods, it is known that if the newly built line is in the general polluted area, the down lead ground wire and the stay rod need to be checked and replaced after  5~7 years and if it is in the heavily polluted area, the service life will be shorter.

Tower down lead ground wire is an important part of the tower lightning arrester, which connects the tower lightning wire with earth wire buried in deep underground.The earth wire is unable to gain access to the rich oxygen, so the corrosion case is not serious, but as a result of down lead ground wire is to connect pole towers above the ground and earth wire buried in the underground,which perennially exposed to contain rich soil moisture and oxygen and air which exacerbated the corrosion situation, so the down lead ground wire between the grounding is the most serious corrosion part of the whole earthing device.
The main cause of corrosion of down lead ground wire and stay rod is serious environmental pollution, accounting for 65%, followed by poor manufacturing process, insufficient galvanized layer or man-made damage and so on.

 
>>------------------------------------------------------------------
China Galvanized Guy Wire Stay Plate Bow Rod

China Galvanized Guy Wire Stay Plate Bow Rod
China Galvanized Guy Wire Stay Plate Bow Rod
China Galvanized Guy Wire Stay Plate Bow RodChina Galvanized Guy Wire Stay Plate Bow Rod
>>------------------------------------------------------------------
China Galvanized Guy Wire Stay Plate Bow Rod


China Galvanized Guy Wire Stay Plate Bow Rod



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now